NLB mKlik Makedonija version 3.3.12 suffers from a remote SQL injection vulnerability.
bfbdc9d4bfa68c32be4a4cd662ca092809eac913783fb0b5a3f2c2c88d4d8312
JM-DATA ONU JF511-TV versions 1.0.67, 1.0.62, and 1.0.55 suffer from cross site request forgery, persistent cross site scripting, default credential, and open redirection vulnerabilities.
c51066c0cb9048b02b75497475a4a15013a17f7c6f79b27527c10c72ae1fc0c9
ECOA building automation systems suffer from an arbitrary file deletion vulnerability. Many versions are affected.
74b68e2af97ce92c0f6145176c6346d99ffdc70d081fbb5279db58eb124bb1b5
ECOA building automation systems suffer from a local file disclosure vulnerability. Many versions are affected.
ab578e3b99dda2c479565b63ee2a81cbdefbf253cf929994b8241910d546052c
ECOA building automation systems suffer from authorization bypass and insecure direct object reference vulnerabilities. Many versions are affected.
2fbaa33171e382ad3ebccde715fa7a4331d3d4391ce1d026f2ab795d2e9a0458
ECOA building automation systems suffer from a remote privilege escalation vulnerability. Many versions are affected.
5d72cdb1a9e256f8aa04a95cc7fda1757d99f39d0120ff44f6e0ad0f1aa9003d
ECOA building automation systems suffer from missing encryption of sensitive information. Many versions are affected.
fbea3c02c7a377cbfc0e1fe62af2f79450fdffd163742edd08eb5f1c1d89ce80
ECOA building automation systems have hardcoded SSH credentials. Many versions are affected.
3b6c0f63a46ae33fbb65a334f754cbd3d76e400e5a655fe28a84047f54567cc0
ECOA building automation systems suffer from a configuration download information disclosure vulnerability. Many versions are affected.
aef4a97a1314e27e1969f3d4e1a72da189d996a3e5a1eb6091e6d19bba339d2d
ECOA building automation systems suffer from a cookie poisoning vulnerability that allows for authentication bypass. Many versions are affected.
9f1383de0fd14fccc3b75dfe56afccaa387d7add8055bd914de409611271ac92
ECOA building automation systems suffer from a cross site request forgery vulnerability. Many versions are affected.
c5e04be1683df924f6735186c911be919b8740e173fc6f468e327ce6ed73c7ee
ECOA building automation systems suffer from directory traversal vulnerability that allows for content disclosure. Many versions are affected.
020d2d4f0280cbde5afa73dac4c8cfd23db4621f938bb3e0bb70091b1c53de10
ECOA building automation systems suffer from path traversal and arbitrary file upload vulnerabilities. Many versions are affected.
ea7f9bd9279b87a7dac72d39679684829a62542b790b1b70e36bca9e2ed2428b
ECOA building automation systems suffer from having default weak credentials. Many versions are affected.
45f0fdd9a7c77effec513c3335453ac15ea81dbffa7b4d63604efe22c99cf375
ECOA building automation systems have hidden backdoor accounts. Many versions are affected.
5338c6d16a6962eaad95acb798ea3fad3c0a94ef6d58971c4a72cb3a313efc07