SAP NetWeaver J2EE Engine version 7.40 suffers from a cryptographic issue that can lead to information disclosure.
4a8752f48a5fa73baa980c9abecb1d2a2c71088e4ae41dc5af67c4faa1a59f5b
Anonymous attackers can use a special HTTP request to inject logs in the xsengine trace file without size restriction. The vulnerability is triggered when the username sent to the /sap/hana/xs/debugger/grantAccess.xscfunc page is longer than 256 characters.
c8c5dd5a2c2a55cdafe1f8d473df9812f164b0f46f07d0a934fb5fc0b3a066f0
SAP NetWeaver J2EE engine version 7.40 suffers from a cross site scripting vulnerability.
4d45bc8c91a6d3d36af7f90ad4341ee0314fc7fffe6fbc4ec7d2cfe5c83dab9f
Debian Linux Security Advisory 3550-1 - enabled and the sshd PAM configuration is configured to read user- specified environment variables and the "UseLogin" option is enabled, a local user may escalate her privileges to root.
374089592e1cd2eb80c2dec50b28b14a5c1a6f12066de2e2c148453d945875cf
Debian Linux Security Advisory 3549-1 - Several vulnerabilities have been discovered in the chromium web browser.
78be013d33903d3148ba3f1b8de4567e0e7e3695de26eaeb437da123767a9de4
PfSense Community Edition versions 2.2.6 and below suffer from cross site scripting, code injection, and cross site request forgery vulnerabilities.
a1cea41cda47aaf708576b8f7af2aa6b3c4f8bef37be1b6afc196e909188eabc
VMware Security Advisory 2016-0004 - VMware vCenter Server, vCloud Director (vCD), vRealize Automation (vRA) Identity Appliance, and the Client Integration Plugin (CIP) updates address a critical security issue.
bd56155a16a9898620437b43f01ad1f323acba62d3f1fc3b322b4be0caad980b
EMC Unisphere for VMAX Virtual Appliance contains a fix for an arbitrary file upload vulnerability. This vulnerability could expose the VMAX Virtual Appliance to be potentially compromised by malicious users. EMC Unisphere for VMAX Virtual Appliance version prior to 8.2.0 are affected.
54c97e2325e2b7e67297fc3d7d82dccdb3972cb5aa3005957194aba7f8158f07
AirOS version 6.x suffers from an arbitrary file upload vulnerability.
a2045ad92aa7807fb104f6e5684803d581ae09e9d5bbb906da255625550214c5
65 bytes small Linux/x86_64 read /etc/passwd shellcode.
838910ad5738b8e6f0bc31928b09825e68de325dc1fb4bedad490fb9acc99c7a
Microsoft Internet Explorer 11 ships with MSHTML.DLL referencing various DLLs which are not present on a Windows 7 SP1 installation, Windows 10 is not affected, other Windows versions have not been tested. According to "MSHTML.DLL is at the heart of Internet Explorer and takes care of its HTML and Cascading Style Sheets (CSS) parsing and rendering functionality." Every application using MSHTML.DLL directly or another DLL which incorporates MSHTML.DLL (like SHELL32.dll) is prone to binary planting.
6527d84b2e81cbfa11caebc6caad25537bf4ae7b3243d2620fd57dda899352a3