EuroTel ETL3100 transmitters use a weak set of default administrative credentials that can be guessed in remote password attacks and gain full control of the system.
01968fa2229cd900e82c526109f7fea321b1e471640bb99f50efbca8c488e208
EuroTel ETL3100 Transmitter Default Credentials
Vendor: EuroTel S.p.A. | SIEL, Sistemi Elettronici S.R.L
Product web page: https://www.eurotel.it | https://www.siel.fm
Affected version: v01c01 (Microprocessor: socs0t10/ats01s01, Model: ETL3100 Exciter)
v01x37 (Microprocessor: socs0t08/socs0s08, Model: ETL3100RT Exciter)
Summary: RF Technology For Television Broadcasting Applications.
The Series ETL3100 Radio Transmitter provides all the necessary
features defined by the FM and DAB standards. Two bands are provided
to easily complain with analog and digital DAB standard. The Series
ETL3100 Television Transmitter provides all the necessary features
defined by the DVB-T, DVB-H, DVB-T2, ATSC and ISDB-T standards, as
well as the analog TV standards. Three band are provided to easily
complain with all standard channels, and switch softly from analog-TV
'world' to DVB-T/H, DVB-T2, ATSC or ISDB-T transmission.
Desc: The TV and FM transmitter uses a weak set of default administrative
credentials that can be guessed in remote password attacks and gain full
control of the system.
Tested on: GNU/Linux Ubuntu 3.0.0+ (GCC 4.3.3)
lighttpd/1.4.26
PHP/5.4.3
Xilinx Virtex Machine
Vulnerability discovered by Gjoko 'LiquidWorm' Krstic
@zeroscience
Advisory ID: ZSL-2023-5782
Advisory URL: https://www.zeroscience.mk/en/vulnerabilities/ZSL-2023-5782.php
29.04.2023
--
Using Username "user" and Password "etl3100rt1234" the operator will enter in the WEB interface in a read-only mode.
Using Username "operator" and Password "2euro21234" the operator will be able also to modify some parameters in the WEB pages.